Grease Selection Guide: NLGI Grades, Thickeners, and Compatibility

Most grease gets chosen on the label. The specification that decides whether it holds up is on the data sheet: the thickener, the dropping point, the water washout figure, and whether it carries the certification your OEM manual asks for. This guide covers how to read those numbers, which thickeners can be mixed and which need the housing cleaned out first, and how much grease a bearing actually takes.


By Stephanie Myers
18 min read

Grease Selection Guide: NLGI Grades, Thickeners, and Compatibility

Grease selection is a specification decision with direct consequences for equipment reliability, service intervals, and maintenance cost. The wrong grade or chemistry in a bearing running at high temperature will fail before its rated service life. The correct selection, matched to operating conditions, load, speed, and environment, keeps the bearing running at rated efficiency through its full drain interval.


Grease Composition

What Grease Is

Grease is a semi-solid lubricant consisting of three components: a thickener, a base oil, and an additive package. The base oil provides lubrication. The thickener holds it in position under operating conditions, releasing oil under mechanical action and reabsorbing it when load eases. Additives modify specific performance properties to suit particular applications.

Each component affects different performance parameters. Selecting grease based on consistency grade alone, without considering thickener type or additive package, is a common cause of premature component failure.

Thickeners

Thickeners give grease its structure. They range from soap-based types (lithium, calcium, aluminium complex, lithium complex) to non-soap types (polyurea, clay, silica). The thickener type directly affects:

  • Temperature tolerance: the upper operating limit and the temperature at which the thickener structure breaks down
  • Water resistance: whether the grease maintains consistency and adhesion in wet conditions
  • Compatibility: not all thickener types are miscible. Mixing incompatible greases can cause softening, oil separation, or rapid degradation
  • Load-bearing capacity: how well the thickener holds the oil film under pressure

Thickener Compatibility

When re-greasing equipment that may contain residue of a previous product, confirm thickener compatibility before applying the new grease. Incompatible thickeners mixed at the bearing can produce a softened or degraded mixture that provides less protection than either product alone.

Table 1 shows compatibility between common thickener types. C = compatible; S = semi-compatible (proceed with caution, purge where possible); I = incompatible (full purge required before switching).

Table 1: Thickener compatibility
Existing grease →
New grease ↓
Li Li-X Ca Ca-X CaS Al-X Poly Clay
Lithium (Li) C C C I I C I I
Lithium Complex (Li-X) C C C I I S S I
Calcium (Ca) C C C C I I I I
Calcium Complex (Ca-X) I I C C S I I I
Calcium Sulfonate I I I S C I I I
Aluminium Complex C S I I I C I I
Polyurea I S I I I I C I
Clay / Bentone I I I I I I I C

Source: Industry compatibility guidance compiled from NLGI and lubricant manufacturer technical data. Semi-compatible combinations vary by formulation; confirm with the product supplier before use.

Published compatibility charts do not fully agree with each other. Lithium complex against aluminium complex is the most disputed pairing in the industry: a review of 21 charts found it rated compatible by 12, borderline by 4, and incompatible by 5. It is shown as semi-compatible here for that reason. Treat any chart as a first pass and confirm a switch with the product supplier using both the thickener types and the base oil types.

For incompatible combinations, disassemble and clean the bearing housing before introducing the new grease. For semi-compatible combinations, purge thoroughly until only the new product exits from the relief valve or seal before returning the equipment to service.

Base Oil Type and Temperature Range

Base oil typically constitutes 80 to 95 per cent of grease by weight. Its viscosity and base oil type together determine the operating temperature range and the film thickness available to separate moving surfaces. Table 2 shows the operating temperature ranges for common base oil types.

Table 2: Base oil types and operating temperature ranges
Base Oil Type Operating Temperature Range Typical Application
Mineral oil -20°C to +120°C General industrial, fleet, agricultural. Most standard applications
PAO synthetic -50°C to +160°C Cold-climate operations, extended drain intervals, high-speed bearings
Ester synthetic -40°C to +200°C High-temperature industrial bearings, electric motors, food-grade applications
Silicone -60°C to +250°C Extreme temperature applications; limited load-carrying capacity
Vegetable / ester (biodegradable) -20°C to +120°C Environmentally sensitive sites, waterways, forestry equipment

Mineral oils cover most standard fleet, agricultural, and industrial applications. Synthetic base oils are specified where the operating temperature falls outside the mineral oil range, where extended drain intervals demand greater oxidation stability, or where environmental regulations require biodegradable formulations.

Viscosity selection within a base oil type depends on operating speed (high-speed applications require lower viscosity) and operating temperature (viscosity drops with temperature, so higher-viscosity base oils are specified for high-temperature applications).

Additives

Additives modify or extend the base performance of the grease beyond what the thickener and base oil alone provide. Common additive functions:

  • Anti-wear (AW): reduce wear between metal surfaces under moderate load
  • Extreme pressure (EP): form a protective layer under high load or shock conditions where the oil film cannot be maintained
  • Corrosion inhibitors: protect metal surfaces from oxidation and corrosion in wet or humid environments
  • Antioxidants: slow oxidative degradation of the base oil, extending service life
  • Solid lubricants: molybdenum disulfide (MoS2) and graphite provide lubrication under extreme load where liquid-film lubrication fails

EP additives are required for gears, heavily loaded bearings, and sliding contact applications. Using a non-EP grease in an EP application accelerates wear and shortens component life. The Four-Ball EP Test (ASTM D2596) on the specification sheet confirms whether a product carries EP performance.


Reading Specification Sheets

Purpose of a Specification Sheet

A grease specification sheet states the product's tested properties and the standards against which it has been evaluated. Reading a spec sheet correctly allows you to confirm whether a grease is suitable for a specific application before use, not after a premature failure.

The key standards referenced on specification sheets are NLGI (National Lubricating Grease Institute), ASTM (American Society for Testing and Materials), DIN (Deutsches Institut fur Normung), and ISO (International Organisation for Standardisation).

NLGI Consistency Grade

NLGI grade measures grease hardness on a scale from 000 (near-fluid) to 6 (solid block). Most bearing and chassis applications use NLGI 1, 2, or 3.

Lower grades (0, 1) are used where low-temperature pumpability is required, in enclosed gear systems, or where centralised lubrication systems need a softer product to flow through lines. Higher grades (2, 3) are specified where leakage must be minimised, where the application involves high temperature, or where the grease must stay in position under heavy vibration.

Specifying NLGI 2 when the application requires NLGI 0 for centralised delivery will block the lubrication system. Using NLGI 0 in an application designed for NLGI 2 will result in grease migration and inadequate coverage at the lubrication point.

Table 3 shows the full NLGI grade scale with consistency and typical application for each grade.

Table 3: NLGI consistency grade scale
Grade Approximate Consistency Typical Application
000 Near-fluid Enclosed gear units, worm gears, very low-temperature applications
0 / 1 Semi-fluid to soft Centralised multi-point lubrication systems, cold-climate bearing applications
2 Butter-like General bearing and chassis applications, wheel bearings. The most widely specified grade
3 Firm High-temperature bearings, vertical shaft applications where grease migration must be minimised
4 to 6 Hard to solid Thread compounds, specialised static sealing applications

NLGI Service Classifications: GC-LB and Related Designations

Beyond the consistency grade, the NLGI Certification Program defines performance designations for specific application categories. These designations appear on product labels and OEM service manuals, and they represent the most direct way to match a product to a specification requirement.

Table 4 covers the designations most commonly encountered in fleet and food-processing applications.

Table 4: NLGI and NSF service designations
Designation Description Common Application
GC-LB Meets both chassis grease (GC) and wheel bearing (LB) performance standards Truck and trailer wheel bearings, fifth-wheel pivots, steering linkages
GC Chassis grease performance only. Not rated for wheel bearing temperatures Ball joints, tie rods, U-joints, suspension pivot points
LB Wheel bearing performance only. High-temperature cycling test Wheel bearing applications where chassis performance is not required
NSF H1 Registered for incidental food contact. Meets FDA 21 CFR 178.3570 Food processing equipment, packaging machinery, beverage handling
NSF H2 No food contact permitted. For use in non-food zones only Conveyors, motors, and ancillary equipment away from product lines

GC-LB is the most common designation in fleet and on-highway transport maintenance. A product carrying GC-LB certification has passed the high-temperature wheel bearing performance test and the chassis grease performance test. When an OEM service manual specifies GC-LB for a wheel bearing application, the grease used must carry that certification, or the warranty claim basis is weakened.

ASTM, DIN, and ISO Standards

ASTM test methods establish performance benchmarks for specific properties: water washout resistance (D1264), wear protection via Four-Ball Wear Test (D2266), load-carrying capacity via Four-Ball EP Test (D2596), oxidation stability, and low-temperature torque (D1478). Each test number references a defined method, allowing comparison between products tested under identical conditions.

DIN 51825 classifies grease by application temperature range, base oil type (mineral or synthetic), consistency range, and corrosion protection level. The classification code provides a compact description of the grease's operating envelope.

ISO 6743-9 classifies lubricating greases for general industrial use by application temperature and load category.

Key Properties on the Specification Sheet

  • Dropping point: the temperature at which the thickener structure breaks down and the grease begins to flow. Operating temperatures should remain at least 50 degrees Celsius below the dropping point to maintain structural integrity. Lithium-complex and calcium-sulfonate greases have higher dropping points than straight lithium.
  • Water washout resistance (ASTM D1264): the percentage of grease lost when subjected to water spray. A product with poor washout resistance in a marine or agricultural application will fail to protect after the first wash-down or rainfall.
  • Four-Ball Wear Test (ASTM D2266): measures wear scar diameter under controlled load. A smaller scar indicates better anti-wear protection.
  • Four-Ball EP Test (ASTM D2596): determines the weld load at which the grease film fails and metal-to-metal contact occurs. Higher weld load indicates greater extreme-pressure capacity.
  • Base oil viscosity at 40 degrees C and 100 degrees C: confirms the oil's viscometric profile across the operating temperature range. Both values are needed. Viscosity index (VI) indicates how much viscosity changes between those temperatures.
  • Low-temperature torque (ASTM D1478): confirms pumpability and starting torque at minimum operating temperature. This is the relevant test for cold-climate applications where centralised lubrication systems must deliver grease reliably.

Consequences of Grease Selection

Friction, Film Strength, and Operating Temperature

The primary function of grease is to maintain a lubricating film between moving surfaces, reducing friction and the heat it generates. A grease matched to the application's speed, load, and temperature maintains that film through the full service interval.

A grease with insufficient viscosity at operating temperature fails to maintain film thickness, leading to boundary-layer contact, elevated wear rates, and increased operating temperature. This accelerates both component wear and grease degradation, shortening the interval before regreasing is required.

Component Life

A grease that maintains its structure and film strength across the full service interval protects bearing and gear surfaces from surface fatigue, corrosion, and abrasive wear. Contamination resistance through appropriate thickener type removes a significant contributor to premature bearing failure.

The cost of a correct grease selection is the product cost. The cost of an incorrect selection includes the component, the labour to replace it, and the downtime while the equipment is out of service. For fleet and construction equipment, unplanned downtime typically costs several multiples of the maintenance cost that would have prevented it.

Maintenance Intervals and Grease Consumption

Matching grease to operating conditions also determines how long it remains effective before reapplication is required. Over-greasing wastes product and can damage seals. Under-greasing through use of a product that degrades before the specified interval leaves the component unprotected.

In high-temperature applications, switching from a standard lithium grease to a lithium-complex or calcium-sulfonate product with higher thermal stability extends the regreasing interval and reduces grease consumption at those temperatures, while maintaining equivalent protection.


Application-Specific Selection

Agricultural Machinery

Agricultural equipment operates across a wide range of conditions: high dust and soil contamination, significant moisture exposure including water immersion of pivot points on irrigation equipment, wide temperature swings between seasons, and long periods of storage between operational windows. Each condition imposes a consequence if the grease is not matched to it.

Poor water resistance in a pivot point or wheel bearing allows moisture to displace the grease film, leaving metal-to-metal contact. Once contamination from soil or dust bypasses inadequate sealing, the abrasive particles accelerate wear at the contact zone faster than any service interval can compensate. Equipment stored seasonally presents a different failure: a grease without genuine corrosion protection will allow rust to pit bearing surfaces during the months it sits unused, and the damage is present before the machine turns a wheel at the start of the next season. Under sustained field vibration, a grease that loses mechanical stability softens progressively and migrates out of the housing, leaving the bearing dry.

Lithium-complex and calcium-sulfonate greases address these conditions in agricultural applications. Calcium-sulfonate is commonly preferred where rust protection is the dominant concern, because its inherent rust inhibition does not depend on additive packages that deplete over time the way supplemented lithium products can.

Construction Machinery

Construction equipment faces high static and dynamic loads, water exposure from rainfall and pressure washing, and severe contamination from soil, sand, and concrete. Earthmoving equipment carries additional requirements around high-temperature performance at pin-and-bush joints operating under sustained heavy load.

Insufficient EP capacity at pins, bushings, and slew rings allows metal-to-metal contact under peak load, causing accelerated wear at the joint surface. A grease that thins excessively under the mechanical shear of oscillating joints loses its protective film at precisely the moment load is highest. Water from pressure washing or rain that displaces a poorly resistant grease leaves the contact surfaces exposed to corrosion between operating cycles. At pin-and-bush joints on excavators and dozers running sustained duty cycles, a grease with an inadequate dropping point will liquify and drain from the housing, leaving the joint dry before the next service point.

Lithium-complex, calcium-sulfonate, and polyurea greases are used in construction applications. The selection between them depends on the specific equipment, the OEM specification, and the conditions at the site.

Heavy-Duty Industrial Machinery

Steel mills, processing plants, and manufacturing facilities require greases capable of sustained performance at elevated temperature, under high load, and in the presence of water and steam. Centralised lubrication systems impose additional requirements around pumpability, particularly at low ambient temperatures.

Without adequate EP and anti-wear capacity, contact surfaces in high-load industrial bearings show fatigue spalling well before their design life. A grease that oxidises and hardens over extended service intervals becomes abrasive rather than protective, contributing to the wear it was meant to prevent. In processing environments with steam washout, a grease without genuine water and steam resistance will be flushed from the bearing housing entirely, leaving the contact zone dry. For centralised lubrication systems, the failure mode is simpler: a grease that will not pump at the minimum system temperature on a cold morning simply does not reach the bearing, regardless of its performance properties at operating temperature.

Calcium-sulfonate and high-performance synthetic greases are used in the most demanding industrial applications. For centralised lubrication systems, pumpability at minimum system temperature must be confirmed from the product data sheet before specifying.

Food Processing and Food-Contact Applications

Equipment in food processing, beverage handling, and packaging requires greases that meet specific regulatory requirements for incidental food contact. Standard industrial greases are not acceptable in these applications, regardless of their performance properties.

NSF H1 registration is required for any lubricant that may have incidental contact with food or beverage products. NSF H1 greases are formulated from white mineral oil or synthetic base stocks approved under FDA 21 CFR 178.3570, with food-grade thickeners and additives. They carry lower load-carrying capacity than equivalent industrial greases, which must be factored into the selection.

NSF H2 greases are used in non-food-contact zones of food processing facilities: motors, conveyors, and ancillary equipment positioned away from product lines. They are not registered for food contact and must not be used in areas where contamination of the product stream is possible.

The H1 or H2 designation should appear on the product label and the NSF registration database. Do not rely on supplier marketing claims alone when selecting for food-contact applications.

Environmentally Sensitive Applications

Applications in or near waterways, marine environments, forestry operations, and other ecologically sensitive areas may require biodegradable lubricants. Standard mineral-oil-based greases are persistent in the environment if released through seal leakage or equipment failure.

Biodegradable greases typically use vegetable ester or synthetic ester base oils. They meet OECD 301B biodegradability criteria, which requires at least 60 per cent biodegradation within 28 days. The operating temperature range for vegetable ester bases is generally -20 degrees Celsius to +120 degrees Celsius, which covers most agricultural and construction applications.

Biodegradable greases have shorter shelf lives than mineral-oil products (typically 12 to 18 months from manufacture) and require more careful storage to prevent oxidative degradation. Confirm shelf life and storage requirements with the product data sheet before specifying for seasonal or low-turnover applications.


Application Methods

Grease Gun Selection

The grease gun type affects output volume per stroke and the risk of over-pressurising a bearing housing. Table 5 covers the most common types used in fleet and workshop applications.

Table 5: Grease gun types, output and risk
Grease Gun Type Approx. Output Best Use Risk
Lever / hand pump 1–2 g per stroke General workshop use, occasional greasing Low. Easy to control volume per point
Pistol grip 1–2 g per stroke One-hand operation in confined spaces Low. Same output as lever type
Battery-powered Consistent output, varies by model High-volume greasing rounds, fleet maintenance Medium. Consistent but can over-grease if interval not controlled
Pneumatic High. 5–8 g per stroke or continuous High-volume applications, centralised filling High. Very easy to blow seals if not used with care

For standard workshop greasing rounds, a lever or pistol-grip gun provides adequate control. Pneumatic guns should be used with a pressure-limiting coupler and a controlled stroke count, not held open continuously. Over-pressurising a bearing housing with a pneumatic gun is one of the most common causes of seal failure in workshop environments.

Calculating Grease Quantity

The standard formula for bearing regreasing quantity is:

G = 0.005 × D × B

Where G = grease quantity in grams, D = bearing outside diameter in millimetres, and B = total bearing width in millimetres. Use the outside diameter, not the bore. Substituting the bore diameter under-specifies the quantity at every point on the fleet.

This formula gives the quantity for a normal regreasing interval on a clean, correctly filled bearing. For initial fill after disassembly, fill the bearing cavity to approximately one-third of its volume for high-speed applications, or two-thirds for low-speed applications. Overfilling generates heat through churning and shortens bearing life.

Example: a bearing with a 110 mm outside diameter and a 22 mm width requires 0.005 × 110 × 22 = 12.1 g per regreasing interval. A standard lever gun stroke delivers approximately 1.5 g, so approximately 8 strokes.

Re-Greasing Intervals

OEM service manuals specify the regreasing interval for each lubrication point. Where no OEM interval is available, the interval depends on operating speed, temperature, load, and contamination exposure.

As a starting point, bearing manufacturers' tables (SKF, NSK, FAG, and similar) provide interval calculations based on bearing type, speed factor (n x dm, where n = speed in rpm and dm = mean bearing diameter in mm), and operating temperature. These are available in the respective bearing catalogues and online tools.

Adjust the baseline interval down (more frequent greasing) for:

  • Operating temperatures above 70 degrees Celsius (halve the interval for every 15 degrees Celsius above this threshold)
  • Severe contamination: water ingress, abrasive dust, or chemical exposure
  • Vertical shaft orientation (grease migrates away from the bearing more readily)
  • Shock or vibration loading

Adjust the interval up (less frequent greasing) where operating temperatures are low, contamination is minimal, and loads are light and constant.

Purging Procedure When Switching Products

When the new and existing greases are compatible: apply new grease through the fitting until fresh product exits from the relief valve or seal, confirming the old product has been displaced. Wipe clean and return to service.

When the thickener types are semi-compatible or incompatible: disassemble the bearing housing, clean all old grease from the housing, bearing, and seal areas, pack with the new grease, and reassemble. Do not attempt to purge incompatible thickeners in situ. The mixed product at the bearing during purging provides degraded protection.

Warning Signs of Incorrect Greasing

A technician checking recently greased equipment can identify incorrect greasing from these indicators:

  • Bearing running hot: either insufficient grease reaching the contact surfaces, or too much grease causing churning and heat build-up
  • Grease leaking from seals: over-greasing, a grease that is too soft (low NLGI grade) for the application, or a damaged seal
  • Discoloured grease at the seal: dark brown or black grease indicates oxidation or contamination; grey grease can indicate metallic wear particles
  • Softened or separated grease on inspection: oil bleed from the thickener structure, indicating thermal degradation, thickener incompatibility, or exceeded shelf life
  • Noise or vibration from bearing: insufficient lubrication or contamination in the contact zone

Storage and Shelf Life

Shelf Life by Product Type

Grease shelf life depends on the thickener type, base oil type, and storage conditions. Table 6 shows typical shelf lives for common product categories under correct storage conditions.

Table 6: Typical shelf life by product type
Thickener Type Typical Shelf Life (sealed) Storage Notes
Lithium / lithium complex (mineral oil) 2–3 years Store at 5°C to 35°C. Avoid temperature cycling above 40°C.
Calcium / calcium sulfonate 2–3 years Good water resistance aids storage stability in humid environments.
Lithium / lithium complex (synthetic PAO) 3–5 years PAO base provides better oxidation stability in storage.
Biodegradable (vegetable / ester) 1–2 years Lower oxidation stability. Keep sealed, cool, away from direct light.

Shelf life figures assume product is kept sealed in original packaging, stored between 5 degrees Celsius and 35 degrees Celsius, away from direct sunlight and heat sources, and not subjected to repeated temperature cycling. Opened containers have shorter effective shelf life.

The manufacture date or shelf life expiry date appears on the product label. Implement first-in, first-out (FIFO) stock rotation to ensure product is used within its shelf life.

Storage Conditions

Temperature cycling is the most common cause of premature grease degradation in storage. Repeated heating and cooling causes oil separation (bleeding) from the thickener structure. A drum stored outdoors in an unshaded area can reach 60 to 70 degrees Celsius on a hot day, then cool overnight. After several cycles, even a correctly specified grease can arrive at the bearing in a degraded state.

Specific requirements for correct storage:

  • Store in a covered, climate-controlled space where possible
  • Keep containers sealed until use. Partially used containers should be resealed tightly after each use
  • Store drums and pails on their sides (horizontal) or with bungs facing up. Vertical storage with a bung at the bottom allows oil bleed to accumulate below the outlet
  • Do not store directly on concrete floors. Pallets or racking provide air circulation and reduce conductive heat transfer
  • Segregate by product type and label clearly to prevent cross-contamination

Identifying Degraded Grease

Before applying stored grease, check for these signs of degradation:

  • Oil pooling on the surface of the grease or inside the lid of the container
  • Hardened or cracked surface layer, with softer product below
  • Change in colour from the original product colour (darkening or discoloration)
  • Grainy or lumpy texture, indicating thickener structure breakdown

Do not use grease showing these signs. The product may have lost its ability to maintain a protective film at the bearing. The cost of replacing degraded product is substantially lower than the cost of a bearing failure caused by applying it.


The Selection Process

Five Factors to Confirm

Selecting grease for a given application requires confirming five factors against the product data:

  1. Operating temperature range (minimum and maximum): confirmed against the grease's dropping point and low-temperature torque data
  2. Load type and magnitude: determines whether AW or EP additives are required
  3. Operating speed: drives base oil viscosity selection
  4. Environmental exposure: moisture, contamination, chemical contact, food contact, or environmental sensitivity
  5. OEM specification, where one exists. The grease must meet the stated standard or designation (such as GC-LB) or warranty coverage may be affected

Worked Example: Truck Wheel Bearing

The following example works through a grease selection for a common fleet application: wheel bearings on a heavy vehicle trailer axle.

Application details

  • Equipment: semi-trailer tandem axle, disc-braked hub unit
  • Operating temperature: -5 degrees Celsius (winter overnight) to +130 degrees Celsius (extended highway brake application)
  • Load: high radial and axial load, intermittent shock from road surface
  • Speed: moderate (road speed)
  • Environment: exposed to rain, road spray, and pressure washing during maintenance
  • OEM specification: NLGI GC-LB

Selection logic

  • GC-LB certification required: this immediately limits the field to products that have passed both the chassis grease performance test and the high-temperature wheel bearing test
  • Operating temperature to +130 degrees Celsius: the dropping point must be well above 180 degrees Celsius. Lithium-complex and calcium-sulfonate greases both qualify. Straight lithium (dropping point typically 175 to 185 degrees Celsius) is borderline and should be avoided for this application
  • Water exposure: water washout resistance (ASTM D1264) should be below 10 per cent weight loss. Most NLGI GC-LB certified products meet this
  • Consistency: NLGI 2 is standard for wheel bearing applications at road speeds

Result

Specify an NLGI GC-LB certified lithium-complex NLGI 2 grease with a dropping point above 260 degrees Celsius, water washout resistance below 10 per cent, and a Four-Ball EP weld load above 250 kg. Confirm the product's technical data sheet against these values before committing.

Regreasing interval: follow the hub manufacturer's service specification. Typical intervals for sealed or semi-sealed disc brake hub units range from 100,000 km to 200,000 km, or as specified by the vehicle OEM's service schedule, whichever comes first.

Regreasing quantity: if the hub unit is opened for inspection, use the formula G = 0.005 × D × B to determine pack quantity, then confirm against the manufacturer's specified fill volume for the hub unit.

Where to Start

Review the equipment's service manual for the OEM grease specification and service interval. Cross-reference to products approved to that standard. If no OEM specification exists, identify the operating temperature range, load type, and environmental conditions, then select from the relevant product data sheets.

If the application involves unusual conditions including extreme temperatures, corrosive environments, food-grade requirements, or specific regulatory compliance, confirm the selection with a technical representative before committing. An incorrect selection costs more to correct after a failure than before one.

Compatibility Check Before Switching Products

When changing grease product on equipment already in service, check Table 1 for thickener compatibility before switching. For incompatible combinations, disassemble and clean before introducing the new product. For semi-compatible combinations, purge until only fresh product exits. For compatible combinations, purge in situ and return to service.

If compatibility is uncertain, contact the product supplier with the thickener types of both products before proceeding.