How does a Sy-Klone pre-cleaner work?
Vanes at the inlet spin the incoming air into a cyclone. Heavier particles and moisture are thrown to the outside wall and expelled through ejection slots, while the cleaner air passes through the centre to the air cleaner. There's no bowl to empty, but the unit still needs checking for blocked slots, cracks and secure mounting at each filter service.
How do I size a Sy-Klone?
Start with the engine's maximum airflow and pick a model whose rated range includes it, ideally near the middle. Then check the outlet matches the intake pipe. Where models share an outlet size, airflow decides between them. If the engine's airflow figure isn't to hand, the engine maker or the OEM manual will have it.
Horizontal or vertical mounting?
Follow the intake. Vertical mounting suits an upright stack, while horizontal mounting suits intakes that come out the side of a bonnet or engine bay. Make sure the ejection slots aren't blocked or aimed at the operator or another intake.
- Engine maximum airflow
- Intake pipe outside diameter
- Mounting orientation
- Clearance around the ejection slots
- Dust, moisture and debris type
Weighing up other types? Compare TopSpin and Full View pre-cleaners, see all pre-cleaners, or send us your airflow figure.