Coolant, radiator flush and coolant test strips for diesel trucks, earthmoving and mining gear, gensets, tractors, 4WDs and cars. Coolant does more than stop freezing: it lifts the boiling point, moves heat out of the engine and delivers the inhibitors that stop corrosion, scale and liner pitting. Choosing comes down to chemistry first, such as OAT or hybrid, and then format, because premix pours straight in while concentrate is mixed with demineralised water.

Match the type the engine maker specifies and don't top up with a different chemistry. Coolant fails quietly. The wrong type, a mixed system or inhibitors run past their life let cavitation, pitting and scale do damage you only find at overhaul. The notes below explain types, testing and changeovers.

Coolant & Radiator Flush

9 products

  • Fleetguard CC2602AM 3-Way Heavy Duty Coolant Test Strips, PGXL HD, 4 Strip Pack
    Vendor:
    Fleetguard

    CC2602AM 3-Way Heavy Duty Coolant Test Strips, PGXL HD, Box of 100 (25 x 4 Strip Packs)

    Regular price $12.50 AUD
    Sale price $12.50 AUD Regular price
  • Fleetguard CC2718 Quick-Chek 3-Way Coolant Condemnation Test Strips, 10 Strip Kit
    Vendor:
    Fleetguard

    CC2718 Quick-Chek 3-Way Coolant Condemnation Test Strips, 10 Strip Kit

    Regular price $16.20 AUD
    Sale price $16.20 AUD Regular price
  • Fleetguard CC2602M 3-Way Heavy Duty Coolant Test Strips, PGXL HD, 50 Strip Bottle
    Vendor:
    Fleetguard

    CC2602M 3-Way Heavy Duty Coolant Test Strips, PGXL HD, 50 Strip Bottle

    Regular price $100.50 AUD
    Sale price $100.50 AUD Regular price
  • Fleetguard CC36089 4-Way Coolant Test Strip Kit
    Vendor:
    Fleetguard

    CC36089 4-Way Test Strip Kit

    Regular price $82.70 AUD
    Sale price $82.70 AUD Regular price
  • Cummins PGXLVITAL-20L PGXL Vital – Advanced Extended Life Heavy Duty Coolant Premix 20L
    Vendor:
    Cummins

    PGXLVITAL-20L PGXL Vital, Advanced Extended Life Heavy Duty Coolant Premix 20L

    Regular price $208.20 AUD
    Sale price $208.20 AUD Regular price
  • Cummins PGXLVITAL-10L PGXL Vital – Advanced Extended Life Heavy Duty Coolant Premix 10L
    Vendor:
    Cummins

    PGXLVITAL-10L PGXL Vital, Advanced Extended Life Heavy Duty Coolant Premix 10L

    Regular price $105.10 AUD
    Sale price $105.10 AUD Regular price
  • Cummins PGXLVITAL-5L PGXL Vital – Advanced Extended Life Heavy Duty Coolant Premix 5L
    Vendor:
    Cummins

    PGXLVITAL-5L PGXL Vital, Advanced Extended Life Heavy Duty Coolant Premix 5L

    Regular price $53.00 AUD
    Sale price $53.00 AUD Regular price
  • Valvoline 0953.20 OEM Advanced 05 Coolant Concentrate 20L
    Vendor:
    Valvoline

    0953.20 OEM Advanced 05 Coolant Concentrate 20L

    Regular price $229.00 AUD
    Sale price $229.00 AUD Regular price
  • Valvoline 0953.05 OEM Advanced 05 Coolant Concentrate 5L
    Vendor:
    Valvoline

    0953.05 OEM Advanced 05 Coolant Concentrate 5L

    2 in stock
    Regular price $62.65 AUD
    Sale price $62.65 AUD Regular price

OAT or hybrid coolant: what's the difference?

OAT coolants protect for long intervals without additives, while hybrids are maintained with SCA. Organic acid technology (OAT) coolants are usually nitrite-free and need no supplemental coolant additive. Hybrid coolants combine organic acids with conventional inhibitors and are topped up with SCA, as a liquid or through a coolant filter, to keep diesel cylinder liners protected. Some engines, including many European cars, call for a silicated OAT. Colour is no guide to chemistry, so go by the spec on the label.

Premix or concentrate?

Premix is ready to use, while concentrate lets you set the strength. Mix concentrate with demineralised water, because the minerals in tap or bore water can form scale and use up inhibitors.

Do you need glycol freeze protection?

Yes, wherever the engine might see frost. Glycol coolants protect against freezing and raise the boiling point. Water-based coolants without glycol carry corrosion inhibitors only, and suit engines that never see sub-zero temperatures, where the engine maker approves them.

How do you change coolant type?

Flush first, never mix. Different chemistries dilute each other's protection, so drain the old coolant, clean the system with a radiator flush, rinse with clean water, then refill with the new type. Afterwards, test strips confirm freeze protection, inhibitor or SCA level and whether the coolant is due for replacement. Use the strip made for that chemistry.

  • Chemistry the engine maker specifies: OAT, hybrid or silicated OAT.
  • Premix or concentrate, and your water quality.
  • Glycol or water-based, depending on frost risk.
  • SCA maintenance for hybrid systems.
  • Test strips that match the coolant.

Fit new coolant filters at the change, and add a heavy-duty diesel engine oil if the oil is due too. Not sure what's in the engine? Tell us the engine and the coolant it calls for.

Which coolant does my engine need?

The one your engine maker specifies. Find the coolant specification in the operator's manual, such as Cummins CES 14603, John Deere JDM H24 or VW TL 774-G, and check it against the approvals in the comparison table on this page. Don't go by colour: OEM Advanced 05 and RCP Platinum are both green but are different chemistry.

  • Heavy-duty diesel already set up for SCA or DCA4 filters: PGXL HD, a nitrite hybrid premix, or OEM Advanced 05, a nitrite-containing concentrate used with SCA as the engine maker specifies.
  • One coolant for a mixed fleet, with no SCA: PGXL Vital, a nitrite-free premix Cummins recommends from heavy-duty wet-liner engines to passenger cars, or PrixMax MEG95, a nitrite-free concentrate. Neither suits an engine whose builder requires a nitrite-inhibited coolant.
  • VW group G12++, MAN 324 Si-OAT, Mercedes-Benz 326.6 or Scania: OEM Advanced 40.
  • BMW LC-87, Mercedes-Benz 325.0 or VW TL-774-C: OEM Advanced 48, a blue low-silicate, phosphate-free hybrid concentrate also approved for MAN 324 NF, Deutz and MTU.
  • GM DEX-COOL (GM 6277M): DEX-COOL, an orange OAT concentrate with no silicates, phosphates or nitrites, in 5L or 20L.
  • Machines that never see frost: RCP Platinum, water-based with no glycol and no freeze protection.
  • Farms and sites where stock or dogs can reach a spill: PGXL Vital and PGXL HD are propylene glycol, which Cummins describes as much lower in toxicity than ethylene glycol.

If your manual calls for a specification that isn't in the table, send it to us and we'll source a coolant that meets it.

What's the difference between PGXL Vital and PGXL HD?

Both are Cummins propylene glycol premixes approved to CES 14603 and CES 14439. PGXL Vital is a nitrite-free OAT coolant that needs no SCA or chemical filter, rated 6 years, 1.5 million km or 36,000 hours. PGXL HD is a hybrid with nitrite and molybdate, maintained at 0.3 to 0.8 SCA units per litre with DCA4 filters, rated 5 years, 1 million km or 20,000 hours. Stay with HD if your engine already runs DCA4 chemical filters, or switch to Vital to drop SCA testing.

Does PrixMax RCP Platinum protect against freezing?

No. RCP Platinum is a water-based OAT coolant with no glycol, which is why it transfers heat better than glycol coolants. It suits engines that never see frost. Where sub-zero temperatures are possible, use a glycol antifreeze such as PrixMax MEG95, which protects to -37°C mixed 50/50, or PGXL Vital, PGXL HD or Valvoline OEM Advanced.

Premix or concentrate: which do I need?

PGXL Vital and PGXL HD are premixed and go straight in, so the mix is always right, including for top-ups. Concentrates make more coolant per pack: MEG95 is mixed at 50% (never below 33% or above 67%), so the 5L makes 10L of coolant. RCP Platinum goes in at 7.5% (75ml per litre of system capacity, never above 10%). Valvoline OEM Advanced 05, OEM Advanced 40, OEM Advanced 48 and DEX-COOL are mixed 50% for protection to -36°C, unless the vehicle manual says otherwise.

Mix concentrates with demineralised or good quality water, never hard tap water. Don't top up any of them with plain water: it dilutes the freeze protection and the inhibitors.

Can I top up with a different coolant?

It's best not to. Mixing coolant types dilutes the inhibitors that protect the system. PrixMax says a system holding more than 15% conventional coolant must be treated as conventional, and Cummins warranty cover on PGXL applies to full fills of 100% PGXL. The exception is DEX-COOL, which Valvoline says can be mixed with other GM-approved DEX-COOL coolant. Otherwise top up with the same coolant, and when you change type, flush with PrixMax Radiator Flush, drain and refill.

Which coolant filter do I fit with each coolant?

It depends on whether the coolant is maintained with SCA.

  • PGXL HD: DCA4 chemical filters. On extended service systems up to 80L, a slow-release ES filter such as the WF2126 for Cummins ISX and X15, changed every 250,000km, 4,000 hours or 12 months. On standard service, a DCA4+ filter from the WF2073 (8 units) to the WF2076 (23 units), changed every 20,000km, 250 hours or 12 months, or the non-chemical WF2077 when the SCA level is already high.
  • OEM Advanced 05: Valvoline calls for SCA as the engine maker specifies to keep protecting wet cylinder liners, so fit the charged filter your engine manual lists.
  • PGXL Vital: non-chemical filters only, such as the WF2122 extended service or WF2077 standard service. A chemical filter puts nitrite into a nitrite-free coolant, which shows up as contamination on the test strip.
  • MEG95 and RCP Platinum: no SCA needed.

See all coolant filters.

Which test strips do I need, and how often should I test?

Match the strips to the coolant:

  • PGXL Vital: the CC36089 4-way kit, at least every 12 months, 250,000km or 4,000 hours, and more often in dusty conditions. Any nitrite reading means the coolant has been contaminated by a nitrite coolant, SCA or chemical filter.
  • PGXL HD and other DCA4-maintained coolants: CC2602M 3-way strips (or the CC2602AM box of 100 in sealed 4-packs, for fleets) at least twice a year on extended service systems and at every oil change on standard service, plus a CC2718 Quick-Chek twice a year to confirm the coolant is still fit to keep. Quick-Chek isn't for red or orange coolants such as PGXL Vital and MEG95.
  • RCP Platinum and MEG95: test yearly, which PrixMax's rated service life depends on, and keep RCP at 7.5%.
  • Glycol strength on any glycol coolant: Castrol Coolant Test Strips read glycol and corrosion reserve, but not nitrite or molybdate, so they don't replace the CC2602M on an SCA-maintained engine.

Test between services too. Donaldson notes a leak, a failed water pump or thermostat, or an incompatible fluid can upset a correctly treated system at any time. For the freeze point itself, a refractometer is the most consistently accurate check.