Fleetguard AH19485 OptiAir 400 Series air cleaner. Primary filter, 90 degree outlet, 1.0 to 2.6 m³/min. Plastic housing. Takes AF26116.
The outlet angle on an air cleaner is not a styling choice, and it is the detail most likely to catch you out on a retrofit.
A 90 degree outlet lets the housing sit across the airflow path rather than in line with it, which is what makes it fit in bays where a straight outlet would need an elbow in the ducting. That matters because every elbow you add to an intake run costs pressure drop, and pressure drop at the intake is what the turbocharger has to work against for the life of the machine. Choosing the housing whose outlet already points the right way is better engineering than choosing a straight one and adding a bend.
This is the 400 Series with a primary filter only and a 90 degree outlet, rated 1.0 to 2.6 m³/min.
Worth noting against its straight-outlet equivalent, the AH19474 at 1.0 to 2.6 m³/min: the angled version is rated slightly lower. The bend costs a little capacity, which is exactly the point above, measured.
Plastic construction, standard across the OptiAir range.
The element for this housing is the AF26116. It is the Opti Air 400 series primary, matched to this housing by Fleetguard rather than selected on dimensions.
No cross-references are recorded for this housing. Order against your machine details and we will confirm the configuration and the correct cartridge before you commit.