Fleetguard AH19488 OptiAir 600 Series air cleaner. Primary and secondary, 90 degree outlet, 2.0 to 5.0 m³/min. Plastic housing, 326.9 mm long. Takes AF26117 and AF26118.
At 326.9 mm long with a 90 degree outlet and two elements inside it, this is a housing with a lot going on in a confined package, and that has a service consequence.
Two elements in a compact housing means very little clearance between the primary and the safety element sitting inside it. Getting a loaded primary out without brushing it against the secondary takes deliberate care, and dust knocked off the primary onto the secondary's sealing face is dust sitting exactly where you least want it when the new primary goes in.
Wipe the secondary face and the housing bore before closing up, whether or not you are replacing the secondary itself. It takes a moment and it is the difference between a service that helps and one that introduces the problem it was meant to prevent.
Rated 2.0 to 5.0 m³/min, which is the lowest band in the 600 Series because both the safety element and the angled outlet cost capacity.
Plastic construction, standard across the OptiAir range.
The elements for this housing are the AF26117 primary and the AF26118 (not currently stocked) safety element. Both are specified by Fleetguard for the Opti Air 600 series, so the pairing is not a judgement call. Order them together and the housing is complete.
No cross-references are recorded. Order against your machine details and ask us which primary and safety cartridges it takes.