Fleetguard AH19489 OptiAir 600 Series air cleaner. Primary filter, 90 degree outlet, 2.4 to 6.0 m³/min. Plastic housing. Takes AF26117.
Mounting orientation is the thing to settle before you order any air cleaner housing, and it is settled more often by what is in the way than by what is ideal.
An air cleaner needs clearance in three directions that people forget: enough space to get the cover off, enough to withdraw the element without bending it, and enough that the inlet is not drawing air off a hot surface or straight out of the wheel arch. A 90 degree outlet frees up the third one, because it lets the body sit where the space is rather than where the ducting points.
Measure the element withdrawal clearance specifically. It is the one that gets missed, and a housing you cannot service without removing a panel is a housing whose element does not get changed.
This is the 600 Series with a primary filter only and a 90 degree outlet, rated 2.4 to 6.0 m³/min. Plastic construction.
The element for this housing is the AF26117. It is the Opti Air 600 series primary, matched to this housing by Fleetguard rather than selected on dimensions.
No cross-references are recorded for this housing. Order against your machine details, and send us a photograph of the installation if you are unsure whether the angled or straight version suits the space. It is easier to resolve before the parts arrive.