Fleetguard AP8404 self-cleaning pre-cleaner. 152.4 mm outlet, 14.16 to 18.41 m³/min, 332.74 mm wide, 281.94 mm high. Ejects 85% of contamination.
At a 152.4 mm outlet this unit is feeding a large air cleaner on serious equipment, and at that scale the economics of pre-cleaning change.
Ejecting 85% of incoming contamination before it reaches the air cleaner is what makes a pre-cleaner worth its fitting cost, and on a machine this size the arithmetic is blunt. If your primary element is loading in 200 hours, removing most of what reaches it does not extend that by a few percent. It changes the service interval enough to notice on the parts bill.
On a small machine a pre-cleaner saves you element changes. On a machine drawing 18 m³/min the element itself is expensive, the housing is large enough that changing it is a job rather than a task, and the machine is usually earning money while it does it. The pre-cleaner is protecting a cost that is measured in downtime as much as in parts.
The mechanism is centrifugal separation. Incoming air is set spinning inside the body, heavier particles are thrown outward by that rotation and ejected before they reach the air cleaner. On quarrying, harvesting and earthmoving duty that stage carries the bulk of the dust load, which is what allows a primary element to reach its published interval instead of a fraction of it.
Rated for 14.16 to 18.41 m³/min. Horizontal or vertical mounting, which is usually what decides whether a retrofit is possible on an existing machine.
Confirm your engine demand sits inside the range and that the outlet matches your ducting before ordering. Undersized pre-cleaning creates restriction rather than protection.