Fleetguard HF6887 hydraulic cartridge filter. 160 lpm to ISO 16889, 300 kPa bypass, 144 mm long, 74 mm OD. Replaces Hydac 2065628, Rexroth R928017506, Eaton 31058510VG.
Hydraulic systems do not tolerate contamination the way engines do. Servo valves and piston pumps hold clearances finer than a lube filter is asked to protect, and the failure mode is not gradual wear but erratic operation followed by an expensive rebuild.
The HF6887 is a hydraulic cartridge element rated at 160 lpm and tested to ISO 16889, the multi-pass standard that reports filtration performance as a beta ratio sustained across the element's service life rather than a single-pass figure. A bypass valve is fitted and opens at 300 kPa. That bypass is a deliberate design decision: when the element loads out or the fluid is cold and viscous, the system continues to receive flow rather than starving the pump or collapsing the element into the circuit.
At 160 lpm this is a substantial flow rating, placing the element in return-line or medium pressure service on machines with meaningful hydraulic demand rather than in a compact auxiliary circuit.
Cartridge construction means the element is replaced within a retained housing, so the seals supplied with the element must be used and the housing bore inspected at every change.
Coverage runs across the European hydraulic component manufacturers whose filters appear on machinery across construction, materials handling and industrial plant: Hydac, Rexroth, Eaton, Eppensteiner and Behringer.
Cross-references confirmed across 7 OEM and aftermarket brands, including Hydac 2065628 and 2063823, Rexroth R928017506 and RFV160G10, Eaton 31058510VG, Eppensteiner 10160LAH10XL0006P, and Hifi SH74002. Full cross-reference table in the specifications tab below.
Verify the element length and outer diameter against the element you are removing, and confirm your housing bypass setting matches 300 kPa, before ordering. Fitting an element with the wrong bypass characteristic into a hydraulic circuit changes when unfiltered fluid reaches your components.