Hydraulic Filters (648)

Hydraulic filters keep the oil clean in the circuits that drive excavators, loaders, tractors, cranes, presses and industrial power units. Pumps, valves and cylinders run very tight clearances, and fine particles cause most of their wear. This department brings together spin-on filters, replacement elements, filter heads and housings, add-on kits and service indicators. Micron rating, pressure rating and media decide the choice. Too coarse and fine particles wear pumps and seals. Too fine for the flow and the filter loads up early, goes into bypass and passes dirty oil anyway. Start with the filter type or hardware you need, in the guide further down the page.

Hydraulic Filters

648 products

  • Fleetguard HF6700 Hydraulic Filter – Spin-on
    Vendor:
    Fleetguard

    HF6700 Hydraulic Filter- Spin-on

    Regular price $63.80 AUD
    Sale price $63.80 AUD Regular price
  • Fleetguard HF6535 Hydraulic Filter – Spin-on
    Vendor:
    Fleetguard

    HF6535 Hydraulic Filter- Spin-on

    3 in stock
    Regular price $24.70 AUD
    Sale price $24.70 AUD Regular price
  • Fleetguard HF6357 Hydraulic Filter – Cartridge
    Vendor:
    Fleetguard

    HF6357 Hydraulic Filter- Spin-on

    1 in stock
    Regular price $47.50 AUD
    Sale price $47.50 AUD Regular price
  • Fleetguard HF6201 Hydraulic Filter – Cartridge
    Vendor:
    Fleetguard

    HF6201 Hydraulic Filter- Cartridge

    Regular price $32.20 AUD
    Sale price $32.20 AUD Regular price
  • Fleetguard HF35549 Hydraulic Filter – Cartridge, Bypass Valve, 1 in Thread
    Vendor:
    Fleetguard

    HF35549 Hydraulic Filter- Cartridge, BPV, 1 in Thread

    3 in stock
    Regular price $74.20 AUD
    Sale price $74.20 AUD Regular price
  • Fleetguard HF35256 Hydraulic Filter – Spin-on, Bypass Valve
    Vendor:
    Fleetguard

    HF35256 Hydraulic Filter- Spin-on, BPV

    Regular price $129.90 AUD
    Sale price $129.90 AUD Regular price
  • Fleetguard HF28783 Hydraulic Filter – Spin-on
    Vendor:
    Fleetguard

    HF28783 Hydraulic Filter- Spin-on

    4 in stock
    Regular price $21.50 AUD
    Sale price $21.50 AUD Regular price
  • Baldwin PT9191 Hydraulic Filter – Cartridge, 40 micron
    Vendor:
    Baldwin

    PT9191 Hydraulic Filter- Element, 40 Mic

    Regular price $158.20 AUD
    Sale price $158.20 AUD Regular price
  • Baldwin PT88-HD Hydraulic / Lube Filter – Full Flow, Cartridge, 45 micron
    Vendor:
    Baldwin

    PT88-HD Hydraulic / Lube Filter- Full Flow, Element, 45 Mic

    Regular price $43.50 AUD
    Sale price $43.50 AUD Regular price
  • Baldwin PT8388 Hydraulic Filter – Cartridge, Reinforced Centertube
    Vendor:
    Baldwin

    PT8388 Hydraulic Filter- Element, Reinforced Centertube

    Regular price $129.80 AUD
    Sale price $129.80 AUD Regular price
  • Baldwin PT8383 Hydraulic Filter – Cartridge, Reinforced Centertube, 25 micron
    Vendor:
    Baldwin

    PT8383 Hydraulic Filter- Element, Reinforced Centertube, 25 Mic

    2 in stock
    Regular price $120.80 AUD
    Sale price $120.80 AUD Regular price
  • Baldwin PT23561-MPG Hydraulic Filter – Cartridge, Synthetic Media, Blank Band
    Vendor:
    Baldwin

    PT23561-MPG Hydraulic Filter- Element, Synthetic Media, Blank Band

    2 in stock
    Regular price $169.20 AUD
    Sale price $169.20 AUD Regular price
  • Baldwin BT8848-MPG Hydraulic Filter – Spin-on, Med Pressure, Synthetic Media, 8 micron
    Vendor:
    Baldwin

    BT8848-MPG Hydraulic Filter- Spin-on, Med Pressure, Synthetic Media, 8 Mic

    Regular price $144.40 AUD
    Sale price $144.40 AUD Regular price
  • Baldwin BT8801-MPG Hydraulic Filter – Spin-on, Med Pressure, Synthetic Media, 8 micron
    Vendor:
    Baldwin

    BT8801-MPG Hydraulic Filter- Spin-on, Med Pressure, Synthetic Media, 8 Mic

    Regular price $171.90 AUD
    Sale price $171.90 AUD Regular price
  • Baldwin BT8512 Hydraulic Filter – Spin-on, Med Pressure, 40 PSI Bypass Valve, 45 micron
    Vendor:
    Baldwin

    BT8512 Hydraulic Filter- Spin-on, Med Pressure, 40 psi BPV, 45 Mic

    Regular price $81.00 AUD
    Sale price $81.00 AUD Regular price

Which hydraulic filter collection do I need?

Suction, pressure or return line?

Where the filter sits sets its job. Suction strainers protect the pump from larger debris, pressure filters protect sensitive valves downstream of the pump, and return filters clean oil before it goes back to the tank. Pressure filters need a housing rated for full system pressure, so never fit a return-line filter on the pressure side.

What is a Beta ratio?

It's a lab measure of how well a filter captures particles of a given size, taken from a multi-pass test. A higher Beta at a given micron size means more particles are caught. It's a more useful comparison than a nominal micron rating, and many machine makers specify a target oil cleanliness code to ISO 4406.

The FAQ below answers common questions. For the oil itself, see hydraulic oil, and for tank breathers see air breathers. Contact us if your housing is unmarked.

What micron rating and efficiency does my hydraulic filter need?

The rating in the machine's service manual, or on the filter you're taking off. Match the micron size and the efficiency together, and keep the media type the same (cellulose or synthetic).

Where the maker gives a target ISO 4406 cleanliness code instead, Fleetguard's selection method starts from the code set for the most sensitive component in the circuit, usually the pump or valves, and the system pressure, then picks the media grade that holds it. In Fleetguard's worked example, construction equipment at 3,000 psi (207 bar) targets 17/15/11, which calls for synthetic media rated β7(c) = 75.

When you compare Beta ratings, check for the (c). It marks the current ISO 16889 test with ISO 11171 particle calibration; older ratings without it used a different calibration, where 5 µm equates to roughly 6 µm(c), so compare like with like.

Only an oil sample with a particle count tells you whether the filter is holding the code.

Should I buy the standard Baldwin hydraulic filter or its -MPG version?

Buy the one the machine maker or the old filter specifies. The -MPG version uses Baldwin's maximum-performance glass (synthetic) media in place of cellulose, often at a finer micron rating on the same mount: BT351 is 27 micron cellulose and BT351-MPG is 8 micron glass, both with a 1-1/4-11 BSP-PL thread and 127 mm across, at 180.2 mm and 177.8 mm long.

Synthetic fibres are smooth and uniform, so they restrict flow less and hold dirt through the depth of the media rather than on the surface. Stepping from 27 to 8 micron also means the filter captures more and may reach capacity sooner, so if you're upgrading for cleaner oil, take an oil sample at the first change to set the interval.

-MPG versions are listed in both our spin-on hydraulic filters and hydraulic elements.

My hydraulic oil keeps testing dirty. Will a finer filter fix it?

Not on its own. A finer element catches more, but in dirty oil it loads faster, so you'll change it more often and it will spend more time close to its bypass point.

Find where the dirt is getting in, then add what stops it:

  • Tank vent: a T.R.A.P. breather keeps dust and moisture out as the oil level rises and falls. Plain dust-only breathers are in air breathers.
  • Off-line clean-up: a Donaldson B.O.S.S. filter cart circulates the tank oil through its own filters, separate from the working circuit, until it's back on target.
  • Wear sources: a worn seal or failing component keeps making debris whatever filter is fitted.

Check progress with regular oil analysis, as Donaldson recommends.

My hydraulic filter's indicator has tripped. What does that mean?

The element is loaded: the pressure drop across it has reached the indicator's set point, which sits below the bypass valve setting. Fleetguard, for example, offers indicators preset at 15 psid (1.03 bar) for heads with a 25 psid (1.72 bar) bypass. Once the bypass opens, oil goes around the element unfiltered, so change the element rather than just resetting the button.

  • Visual indicators: a pop-up button or gauge. Baldwin's visual indicator stays tripped until it's reset, even after the machine is shut down.
  • Electrical indicators: a switch that signals a warning light or the machine's controller.

Cold, thick oil raises the pressure drop across any element in proportion to its viscosity, so an indicator can trip on a cold start. Reset it, and if it trips again with the oil at working temperature, the element is due.

No indicator on the head? Many heads have a spare port for one: see our service indicators.

How often should hydraulic filters be changed?

At the interval in the machine's service schedule, or sooner if the restriction indicator or differential pressure gauge shows the element is loaded. We don't publish a blanket hour figure because it depends on the machine, the work and how dirty the oil is.

Fleetguard sets its electrical indicators to trigger when the element is about 90–95% plugged, and that's the time to change it. Where a head has no bypass valve, a differential pressure gauge is the only warning: run past it and the element can collapse or burst.

Expect short first intervals after a clean-up. In a Donaldson case study, new 7 micron filters on very dirty crusher gearbox oil plugged within two weeks, then settled at a four-month change once the oil was clean.

How much difference does cleaner hydraulic oil make to component life?

A lot. Filter makers put contaminated fluid behind most hydraulic failures: Fleetguard says 90% of them, Donaldson more than 75%.

The gains come in steps on the ISO code. Donaldson, citing Noria's life extension tables, says improving cleanliness by two ISO codes can extend component life by 60%. In its crusher case study, taking gearbox oil from ISO 23/22/19 to 16/14/11 was rated at 3.5 times the gearbox life.

On most machines the cheapest life gain is holding the oil at its target: the right filter grade, changed on time, with a tank breather that stops dirt coming in through the vent.

Do you sell hydraulic filter heads, housings and add-on kits?

Yes. Hydraulic Filter Heads & In-Tank Housings holds Donaldson low-pressure spin-on heads (SP and FBK series), Duramax HMK04 and HMK05 medium-pressure heads, and FIK in-tank return filters. Matching service indicators fit the Duramax heads. For a package that's ready to plumb in, hydraulic filter kits hold the X900017 dual Duramax kit and the K051153 FBK160/200 head supplied with its filter.

If you're specifying from scratch, have the circuit's maximum operating pressure and flow ready. Donaldson's selection method starts with those two figures, then picks the housing, then the element by ISO code, fluid, viscosity and allowable pressure drop.